Start With the Measurement and Protection Duty

A current transformer (CT) scales primary current to a secondary signal used by metering, relays, or monitoring equipment. Define which functions the CT must serve before selecting its ratio or construction: a billing meter, an overcurrent relay, and a differential protection scheme may have different accuracy and performance needs. Record the normal load, expected fault conditions, system grounding, and the devices that will receive the secondary signal. Avoid choosing a ratio solely from a switchgear bus rating; a ratio that is too high for the actual load can reduce useful measurement resolution, while a mismatch can affect protection performance. Share the one-line diagram and instrument or relay requirements with the manufacturer so the assembly can be evaluated as a coordinated design.

02 /

Specify CT Data Alongside the Switchgear

A useful CT schedule identifies each location and intended function, then lists the project-required ratio, accuracy class, burden, secondary rating, polarity, and any special performance criteria. Applicable values depend on the metering or protection application and the selected devices, so confirm them with the engineer of record rather than copying a prior job's schedule. Note whether separate cores or CTs are required for different functions; sharing a secondary circuit may not suit every protection or metering scheme. Also identify the conductor or bus arrangement and available mounting space. These details affect window size, orientation, terminal access, and assembly layout. Resolve discrepancies between drawings, relay submittals, and specifications before release: late changes can affect both the switchgear configuration and the review schedule.

Copper busbars inside electrical equipment, shown for illustration
THE DETAILS BEHIND THE POWERIllustrative photograph; not represented as our facility. Photo: ToT89.
03 /

Check Physical Fit and Electrical Interfaces

The CT must fit around or onto the specified conductor without obstructing bus connections, barriers, insulation, or access needed for inspection. Confirm the equipment configuration, conductor dimensions, cable entry direction, and available compartment space against the project drawings. For retrofit or replacement planning, document the existing CT arrangement and the switchgear manufacturer's information where available; a similar-looking device does not establish dimensional or electrical compatibility. Review secondary terminal locations, wire routing, grounding provisions, and how polarity markings will remain identifiable after assembly. These details matter because cramped routing or obscured markings can complicate commissioning and future troubleshooting. Final fit and interfaces are project-specific and should be reviewed in the context of the complete assembly, not selected from a CT catalog in isolation.

04 /

Coordinate CTs With Protection and Metering Devices

CT performance depends on the connected circuit, not only the CT nameplate. Ask the protection or metering designer to confirm the intended devices, secondary lead arrangement, total circuit burden, and required response under expected operating and fault conditions. Long secondary wire runs, multiple connected instruments, or a changed relay model can alter the circuit assumptions. For differential, ground-fault, or other coordinated protection applications, confirm the CT arrangement and polarity requirements with the responsible engineer; small documentation errors can undermine the intended scheme. Identify any test switches, shorting provisions, or terminal blocks required by the design and show them on the wiring documents. The manufacturer can use approved project information to coordinate assembly interfaces, but should not substitute for the engineer's protection study or settings decisions.

05 /

Plan Submittals, Review, and Release Timing

CT selection can influence compartment layout and control wiring, so include its requirements early in the switchgear inquiry rather than adding them after the design is underway. A purchasing package should include the one-line diagram, CT schedule, wiring diagrams, relay or meter requirements, equipment ratings, and relevant specification sections. Identify who is responsible for reviewing protection details and who can approve deviations. During submittal review, compare the proposed CT data and locations with the latest coordinated drawings, then return consolidated comments to reduce conflicting revisions. Custom equipment and component availability can affect project timing; no schedule should be assumed until requirements and current availability are reviewed. Confirm the required approval and release milestones with the manufacturer, especially when switchgear delivery is tied to construction sequencing.

06 /

Coordinate Delivery, Installation, and Commissioning Records

Before shipment, verify that approved drawings, CT identification, terminal designations, and the field wiring plan describe the same configuration. Coordinate delivery with site access, unloading equipment, indoor storage, and the planned switchgear setting sequence; large assemblies may need a clear route through doors, corridors, or controlled-access areas. Protect equipment from moisture, dust, and construction damage in accordance with its documentation, and keep identification readable. Installation and testing must be performed by qualified personnel under the applicable project procedures, with equipment de-energized and appropriately controlled for the work. Preserve CT nameplate and connection information with commissioning records, including verified polarity and circuit checks as required by the engineer. Accurate records help operators investigate readings or relay events without relying on assumptions about the installed design.

THE DETAILS MATTER

Project
specifications.

Bring your requirements to the conversation. Final configurations are determined by the project scope and applicable standards.

Specifications and project considerations
ParameterProject consideration
ApplicationSwitchgear Current Transformers
Voltage and configurationProject-specific; confirm in quotation
Continuous current and busProject-specific; confirm in quotation
Short-circuit ratingProject-specific; confirm in quotation
Standards and certificationAs applicable; verify for the proposed assembly
Component originAll-American options; confirm in quotation
Lead time and shippingProject-specific; nationwide shipping available
LET'S BUILD SOMETHING

Your project
starts here.

Tell us what you are planning. Share the details you have, and start a conversation about new equipment built for the job.

PREFER TO TALK?
(951) 403-5738
HOUSTON, TEXAS / NATIONWIDE
PROJECT INQUIRY

Request a quote

Fields marked with an asterisk are required.

Submitting opens your email application with your inquiry. Please send the prepared email to complete your request; no information is submitted through this website.

REQUEST A QUOTE